[1]汪建军,余艳丽,任超杰.胶乳增强免疫比浊法两种定量试剂检测D-二聚体的评价[J].现代检验医学杂志,2015,30(05):141-142.[doi:10.3969/j.issn.1671-7414.2015.05.044]
 WANG Jian-jun,YU Yan-li,REN Chao-jie.Evaluation of Two Kinds of Quantitative Reagents for Detection of D-Dimer by Latex Enhanced Immune Turbidity[J].Journal of Modern Laboratory Medicine,2015,30(05):141-142.[doi:10.3969/j.issn.1671-7414.2015.05.044]
点击复制

胶乳增强免疫比浊法两种定量试剂检测D-二聚体的评价()
分享到:

《现代检验医学杂志》[ISSN:/CN:]

卷:
第30卷
期数:
2015年05期
页码:
141-142
栏目:
研究简报·实验技术
出版日期:
2015-12-10

文章信息/Info

Title:
Evaluation of Two Kinds of Quantitative Reagents for Detection of D-Dimer by Latex Enhanced Immune Turbidity
作者:
汪建军余艳丽任超杰
陕西省核工业215医院检验科,陕西咸阳712000
Author(s):
WANG Jian-junYU Yan-liREN Chao-jie
Department of Clinical Laboratory, Nuclear Industry 215 Hospital of Shaanxi Province,Shaanxi Xianyang 712000,China
关键词:
D-二聚体胶乳增强免疫比浊法准确度精密度
分类号:
R446
DOI:
10.3969/j.issn.1671-7414.2015.05.044
文献标志码:
A
摘要:
目的应用胶乳增强免疫比浊法对两种定量试剂(西门子,九强)检测D-二聚体(D-D)的准确度、精密度及检测结果的一致性进行评价。方法收集新鲜凝血标本50份,应用两种不同试剂在sysmex CA-7000全自动凝血分析仪进行D-二聚体检测,比较其检测结果的一致性,通过对质控品的测定来比较两种试剂的精密度和准确度。结果准确度通过检测自身质控品和对方质控品进行评价,西门子试剂检测D-二聚体的相对偏差分别为-2.0%和-8.7%,九强试剂检测D-二聚体的相对偏差分别为-2.2%和26%;精密度通过20次室内质控结果进行评价,西门子试剂的检测均值为4.9±0.19 mg/L,CV为3.88%,差异无统计学意义(t=0.117,P>0.05),九强试剂检测的均值为4.5±0.17 mg/L,CV为3.69%,差异无统计学意义(t=0.132,P>0.05);检测结果一致性的对比显示:在D-D<0.5 mg/L时,两种定量试剂差异无统计学意义(P>0.05);在0.5 mg/L0.05);但在D-D>5 mg/L时,九强试剂显著高于西门子试剂,差异具有统计学意义(P<0.01)。结论两种试剂的精密度良好,准确度在检测对方质控品时结果不令人满意,九强试剂在D-D>5 mg/L时的准确度尚需进一步论证。
Abstract:
ObjectiveTo compare the D-Dimer accuracy and precision and consistency of detection results between the 1 and 2 reagent.MethodsSelected 50 fresh samples,detected D-Dimer with the two reagents on sysmex CA-7000 automated blood coagulation analyzer.Compared the consistency of detection results between them,and detected the accuracy and precision by the control material.ResultsIn order to evaluate the accuracy,detected and analysed its quality control material and other quality control material.The relative deviation were -2% and -8.7% respectively for siemens reagent,and the relative deviation were -2.2% and 26.0% for jiuqiang reagent.The precision was evaluated by 20 internal quality control,the mean of D-Dimer for siemens reagent was 4.9±0.19 mg/L,CV was 3.88%,and the difference was not statistically significant (t=0.117,P>0.05).The mean of D-Dimer for siemens reagent was 4.5±0.17 mg/L,CV was 3.69%,and the difference was not statistically significant (t=0.132,P>0.05).The contrast of the detection results showed that the difference was not significant (P>0.05).When D-D<0.5 mg/L or 0.5 mg/L0.05).But when D-Dimer>5 mg/L,the result of jiuqiang reagent was higher than siemens reagent,and the difference was obvious significance difference (P<0.01).ConclusionThe two reagents,precision was good,the accuracy was not satisfied in the detection of each other quality control material.In the range of D-Dimer>5 mg/L,the accuracy of the latter had to be testified.

参考文献/References:

[1]Maclean KN,Sikora J,Koich V,et al.A novel transgenic mouse model of CBS-deficient homocystinuria does not incur hepatic steatosis or fibrosis and exhibits a hypercoagulative phenotype that is ameliorated by betaine treatment[J].Molecular Genetics and Metabolism,2010,101(2/3):153-162.
[2]Stender MT,Larsen TB,Srensen HT,et al.Preoperative plasma D-dimer predicts 1-year survival in colorectal cancer patients with absence of venous thromboembolism (VTE):a prospective clinical cohort study[J].Journal of Thrombosis and Haemostasis,2012,10(10):2027-2031.
[3]Fan J,Li XY,Cheng YQ,et al.Measurement of D-dimer as aid in risk evaluation of VTE in elderly patients hospitalized for acute illness:a prospective,multicenter study in China[J].Clinical and Investigative Medicine,2011,34(2):96-104.
[4]Kawaguchi T,Kumabe T,Kanamori M,et al.Early detection of venous thromboembolism in patients with neuroepithelial tumor: efficacy of screening with serum D-dimer measurements and Doppler ultrasonography[J].Journal of Neuro-Oncology,2011,101(3):495-504.
[5]Roselli M,Ferroni P,Portarena I,et al.Predictive va-lue of high-sensitive D-dimer determination for chemotherapy-associated venous thromboembolism in gastrointestinal cancer patients[J].Thrombosis and Haemostasis,2012,108(6):1243-1245.
[6]Antovic JP,Hg Hammarstrm K,Forslund G,et al.Comparison of five point-of-care D-dimer assays with the standard laboratory method[J].International Journal of Laboratory Hematology,2012,34(5):495-501.
[7]郭野,寿玮龄,吴卫,等.INNOVANCE试验和PLUS试验检测D-二聚体方法比较[J].中华检验医学杂志,2013,36(7):638-642. Guo Y,Shou WL,Wu W,et al.Method comparison between INNOVANCE D-Dimer and PLUS D-Dimer[J].Clin J Lab Med,2013,36(7):638-642.

相似文献/References:

[1]施瑞洁,刘文康,李博,等.血浆D-D,FDP及血清hs-CRP检测对多发性腔隙性脑梗死的临床意义[J].现代检验医学杂志,2015,30(06):75.[doi:10.3969/j.issn.1671-7414.2015.06.021]
 SHI Rui-jie,LIU Wen-kang,LI Bo,et al.Clinical Study on Plasma D-D,FDP and Sera hs-CRP Test for Multipleh Lacunar Infarction[J].Journal of Modern Laboratory Medicine,2015,30(05):75.[doi:10.3969/j.issn.1671-7414.2015.06.021]
[2]刘 莎,江咏梅,张 鸽,等.两种试剂D-二聚体检测值 与纤维蛋白降解产物值的相关性研究[J].现代检验医学杂志,2015,30(01):108.[doi:10.3969/j.issn.1671-7414.2015.01.030]
 LIU Sha,JIANG Yong-mei,ZHANG Ge,et al.Study of the Correlation of Testing Results by Two Different D-dimer Reagents with Fibrin Degradation Products Result Values[J].Journal of Modern Laboratory Medicine,2015,30(05):108.[doi:10.3969/j.issn.1671-7414.2015.01.030]
[3]张红雨,马兴璇.联合检测D-二聚体和CA153在乳腺癌诊治中的临床意义[J].现代检验医学杂志,2015,30(02):137.[doi:10.3969/j.issn.1671-7414.2015.02.043]
[4]宋文炜.血浆D-二聚体检测对甲状腺癌患者的临床意义[J].现代检验医学杂志,2016,31(06):138.[doi:10.3969/j.issn.1671-7414.2016.06.041]
 SONG Wen-wei.Clinical Significance of Plasma D-dimer Testing in Patients with Thyroid Cancer[J].Journal of Modern Laboratory Medicine,2016,31(05):138.[doi:10.3969/j.issn.1671-7414.2016.06.041]
[5]颜宇飞,邓雪梅,刘明利,等.新型冠状病毒肺炎患者血液NLR,DD和 CRP水平联合检测对死亡风险的评估研究[J].现代检验医学杂志,2021,36(01):92.[doi:10.3969/j.issn.1671-7414.2021.01.023]
 YAN Yu-fei,DENG Xue-mei,LIU Ming-li,et al.Novel Coronavirus Pneumonia Patients’ Blood NLR, DD and CRP Levels Combined Detection for the Evaluation of Death Risk[J].Journal of Modern Laboratory Medicine,2021,36(05):92.[doi:10.3969/j.issn.1671-7414.2021.01.023]
[6]付忠晓,黄 俊,王长征,等.COVID-19患者血浆凝血指标及D-二聚体水平检测对临床分型的鉴别价值[J].现代检验医学杂志,2021,36(02):118.[doi:doi:10.3969/j.issn.1671-7414.2021.02.028]
 FU Zhong-xiao,HUANG Jun,WANG Chang-zheng,et al.Preliminary Study on the Differential Value of Coagulation Indexes and D-dimer Level in the Clinical Classification of COVID-19 Patient[J].Journal of Modern Laboratory Medicine,2021,36(05):118.[doi:doi:10.3969/j.issn.1671-7414.2021.02.028]
[7]谭 雍,严 敏,程 珍,等.433例肺血栓栓塞症患者血液 C-反应蛋白、抗凝血酶和纤维蛋白原及血液学变化特点分析[J].现代检验医学杂志,2022,37(01):203.[doi:10.3969/j.issn.1671-7414.2022.01.042]
 TAN Yong,YAN Min,CHENG Zhen,et al.Analysis of Change Feature of CRP ,Antithrombin, Fibrinogen and Hematological Indexs in 433 Patients with PulmonaryThromboembolism[J].Journal of Modern Laboratory Medicine,2022,37(05):203.[doi:10.3969/j.issn.1671-7414.2022.01.042]
[8]段 玮,刘兴晖,李廷俊,等.基于血液炎症相关指标建立儿童复杂性阑尾炎的预测模型及验证[J].现代检验医学杂志,2023,38(02):155.[doi:10.3969/j.issn.1671-7414.2023.02.029 ]
 DUAN Wei,LIU Xing-hui,LI Ting-jun,et al.Establishment of Predictive Models and Verification Based on Related Inflammatory Factors in Blood of Complex Appendicitis in Children[J].Journal of Modern Laboratory Medicine,2023,38(05):155.[doi:10.3969/j.issn.1671-7414.2023.02.029 ]

备注/Memo

备注/Memo:
作者简介:汪建军(1979-),男,硕士,主管检验师,专业:临床检验,Tel:029-32088143,E-mail:wangjianjun790319@163.com。
更新日期/Last Update: 1900-01-01