[1]王玲萍,许中,陆茜莹,等.干式时间分辨荧光免疫层析法检测血清抗链球菌溶血素“O”的方法学性能验证[J].现代检验医学杂志,2020,35(05):131-133,167.[doi:10.3969/j.issn.1671-7414.2020.05.034]
 WANG Ling-ping,XU Zhong,LU Qian-ying,et al.Validation of Dry Time -Resolved Fluorescence Immunochromatography for Detection of Serum Anti Streptolysin “O”[J].Journal of Modern Laboratory Medicine,2020,35(05):131-133,167.[doi:10.3969/j.issn.1671-7414.2020.05.034]
点击复制

干式时间分辨荧光免疫层析法检测血清抗链球菌溶血素“O”的方法学性能验证()
分享到:

《现代检验医学杂志》[ISSN:/CN:]

卷:
第35卷
期数:
2020年05期
页码:
131-133,167
栏目:
研究简报·实验技术
出版日期:
2020-11-01

文章信息/Info

Title:
Validation of Dry Time -Resolved Fluorescence Immunochromatography for Detection of Serum Anti Streptolysin “O”
文章编号:
1671-7414(2020)05-131-04
作者:
王玲萍1许中2陆茜莹1陆仁伟1周伟3刘琴1
1. 苏州市相城区漕湖人民医院检验科,江苏苏州215144;2. 苏州市立医院东区检验科, 江苏苏州 215001; 3. 上海捷门生物技术有限公司,上海 201806
Author(s):
WANG Ling-ping 1 XU Zhong2 LU Qian-ying 1 LU Ren-wei 1 ZHOU Wei 3 LIU Qin 1
1.Department of Clinical Laboratory,Caohu People’s Hospital of Xiangcheng District in Suzhou, Jiangsu Suzhou 215144,China;2.Department of Clinical Laboratory, Eastern Distric of Suzhou Municipal Hospital, Jiangsu Suzhou 215001,China;3.Shanghai Jiemen Biotechnology Co. Ltd, Shanghai 201806, China
关键词:
抗链球菌溶血素“O”精密度正确度线性试验参考范围
分类号:
R446.62
DOI:
10.3969/j.issn.1671-7414.2020.05.034
文献标志码:
A
摘要:
目的 验证时间分辨荧光免疫层析法抗链球菌溶血素“O”(ASO)检测试剂的方法学性能。方法 参照 CLSI 对上海捷门生物技术有限公司生产的干式时间分辨荧光分析仪(FIT-1000)ASO 荧光免疫层析法检测的精密度、 正确度、线性及参考范围进行验证。并以贝克曼IMMAGE800 免疫散射速率法作为参考系统,对临床标本进行比对实验。 结果 正确度试验,检测ASO 浓度分别为83.2 ,136 和269 IU/ml 的校准品,相对偏倚分别为-1.03%,-0.99% 和-2.70%。 检测低、高两个浓度血清标本的ASO 精密度,CV 分别为8.32%,6.39%。ASO 浓度范围46.37 ~ 868.13 IU/ml 时,线 性方程为Y=0.958 8X-3.889(r2=0.998 5)。临床标本(n=61) 比对实验,Deming 回归方程Y=1.256X-6.51,r=0.950 6。性 能评价项目结果均达到厂商声明标准。结论 应用干式时间分辨荧光分析仪(FIT-1000)及配套试剂检测ASO,其正确性、 重复性良好,可满足临床尤其是基层医疗单位的要求。
Abstract:
Objective To verify the methodological performance of anti streptolysin “O” (ASO) detection reagent by timeresolved fluorescence immunochromatography CTRFIC. Methods According to CLSI, the precision, accuracy, linearity and reference range of ASO fluorescence immunochromatography (FIT-1000) produced by Shanghai Jiemen Biotechnology Co. Ltd were verified. Beckman IMMAGE800 was used as the reference system to compare the clinical samples. Results In the accuracy test, the relative bias was - 1.03%, - 0.99% and - 2.70%, when the ASO concentration was 83.2 , 136 and 269 IU / ml, respectively. The precision of ASO was 8.32% and 6.39% respectively. When the concentration of ASO ranged from 46.37 to 868.13 IU / ml, the linear equation was Y = 0.958 8X-3.889 (r2 = 0.998 5). The Deming regression equation Y = 1.256X-6.51, r = 0.950 6. The results of performance evaluation items all meet the manufacturer’s declaration standard. Conclusion The accuracy and repeatability of dry TRFIC analyzer (FIT-1000) and related reagents for ASO detection are good, which can meet the requirements of clinical, especially primary medical units.

参考文献/References:

[1] 阎东莉,白玉兰,褚云卓,等.A 族β- 溶血性链 球菌咽部分离株临床耐药性分析 [J]. 中华医院感染 学杂志,2016,26(21):4873-4875. YAN Dongli, BAI Yulan, CHU Yunzhuo, et al. Drug resistance of group A β-hemolytic Streptococcus isolated from throat swab[J]. Chinese Journal of Nosocomiology, 2016,26 (21): 4873-4875
[2] Clinical and Laboratory Standards Institute. CLSI EP6-A: Evaluation of the linearity of quantitative measurement procedures:A statistical approach; approved guideline [S ].Wayne:PA, CLSI EP6-A,2003.
[3] 张淑琼,王凡.奥林巴斯AU5400 检测血清抗链球 菌溶血素O 的测量范围评价 [J]. 检验医学与临床, 2014, 11(7): 929,931. ZHANG Shuqiong, WANG Fan. Evaluation of measurement range of olympus AU5400 for detection of serum anti Streptolysin O [J]. Laboratory Medicine and Clinical, 2014, 11 (7): 929,931
[4] 高明,杨晓英,毛晓莉. 抗β2 糖蛋白Ⅰ抗体、糖 膜蛋白GP Ⅰ b 及抗链球菌溶血素O 检测在类风 湿关节炎急性阶段的诊断价值[J]. 国际检验医学杂 志,2019, 40(5):575-578. GAO Ming, YANG Xiaoying, MAO Xiaoli. Diagnostic value of anti-β2 glycoprotein Ⅰ antibody, membrane glycoprotein GP Ⅰ b and anti-streptolysin O in acute stage of rheumatoid arthritis [J]. International Journal of Laboratory Medicine, 2019,40 (5) : 575-578.
[5] 孙立芳,赵 静. 浅谈免疫比浊法技术优势[J]. 中国 民康医学,2012,24(23): 2870-2872. SUN Lifang, ZHAO Jing. Shallowly discusses immunity turbidimetric method technology superiority[J]. Medical Journal of Chinese People’s Health, 2012,24 (23): 2870-2872.
[6] 冯景,周有利. 免疫透射比浊法测定抗链球菌溶 血素O 和类风湿因子[J]. 陕西医学检验, 2001,16 (2):19-20. FENG Jing, ZHAO Youli. The method of determining anti streptolysin-O and rheumatoid factor with immunity transmission turbidity[J]. Shaanxi Medical Laboratory, 2001,16 (2): 19-20
[7] 彭凤,应春妹, 徐晓萍, 等. 免疫透射比浊法与免疫 散射比浊法检测特定蛋白的比较研究[J]. 现代检验 医学杂志, 2011,26(1): 45-47. PENG Feng, YING Chunmei, XU Xiaoping, et al. Study on analysing serum specific proteins by immunoturbidimetric assays and immunonephelometric assays[J]. Journal of Modern Laboratory Medicine, 2011,26 (1) : 45-47.
[8] 汤卫菊. 抗链球菌溶血素“O”试验定量与定性结 果比较[J]. 检验医学与临床, 2009,6(16):1376-1377. TANG Weiju. Comparison of quantitative and qualitative results of anti-streptococcal hemolysin “O” test [J]. Laboratory Medicine and Clinical, 2009,6 (16):1376-1377.
[9] 张会品,张建春,郭兰芳. 风湿热患者血清ASO 滴 度与HDL水平的相关性分析[J]. 现代检验医学杂志, 2018,33(5): 145-148. ZHANG Huipin, ZHANG Jianchun, GUO Lanfang. Clinical evaluation of high density lipoprotein in rheumatic fever[J]. Journal of Modern Laboratory Medicine, 2015,33 (5) : 145-148.
[10] 肖群峰,王飙,赵和平,等. 抗链球菌溶血素O 和类风湿因子定量测定[J]. 国际检验医学杂志, 2010,31(9): 1039-1040. XIAO Qunfeng, WANG Biao, ZHAO Heping, et al. Quantitative determination of anti streptolysin O and rheumatoid factor [J]. International Journal of Laboratory Medicine, 2010,31 (9): 1039-1040.
[11] 韩静,胡梅,杨桂花,等.BN II 特种蛋白仪测定 IgG,IgA 和 IgM 性能评价 [J]. 国际检验医学杂志, 2013, 34(10): 1292-1294. HAN Jing, HU Mei, YANG Guihua, et al. Performance evaluation of the determination of IgG, IgA and IgM by BN II special protein analyzer [J]. International Journal of Laboratory Medicine, 2013, 34 (10): 1292-1294.
[12] 杨娟娟.美国贝克曼库尔特 IMMAGE 800 特种蛋白 仪性能评价 [J]. 国际检验医学杂志, 2016,37(10): 1402-1404. YANG Juanjuan. Performance evaluation of IMMAGE 800 special protein analyzer in Beckman Coulter [J]. International Journal of Laboratory Medicine, 2016, 37 (10): 1402-1404.
[13] 赵超芬. 用三种免疫检验法检测乙型肝炎标志物在 诊断乙型肝炎中的价值[J]. 当代医学论丛,2020,18 (7):183-184. ZHAO Chaofen. The value of detecting hepatitis B markers by three immunoassays in the diagnosis of hepatitis B [J]. Journal of Contemporary Medicine, 2020,18 (7): 183-184.
[14] 赖玉玲,黄丽芳,雷兴. 时间分辨荧光免疫法检测 梅毒螺旋体抗体的临床应用研究[J].中国医药科学, 2019,9(7):111-115. LAI Yuling, HUANG Lifen, LEI Xing.Research on clinical application of time-resolved fluorescence immunoassay for detection of treponema pallidum antibody[J].China Medicine and Pharmacy, 2019,9 (7): 111-115.

相似文献/References:

[1]汪建军,余艳丽,任超杰.胶乳增强免疫比浊法两种定量试剂检测D-二聚体的评价[J].现代检验医学杂志,2015,30(05):141.[doi:10.3969/j.issn.1671-7414.2015.05.044]
 WANG Jian-jun,YU Yan-li,REN Chao-jie.Evaluation of Two Kinds of Quantitative Reagents for Detection of D-Dimer by Latex Enhanced Immune Turbidity[J].Journal of Modern Laboratory Medicine,2015,30(05):141.[doi:10.3969/j.issn.1671-7414.2015.05.044]

备注/Memo

备注/Memo:
作者简介:王玲萍(1988-),女,大专,主管检验师,研究方向:临床检验, E-mail:540280220@qq.com。
通讯作者:刘琴, 副主任技师,主要从事实验室管理及生化检验,E-mail:2297779562@qq.com。
更新日期/Last Update: 2020-10-30