[1]李建刚,赵家宁,徐 华,等.直接抗人球蛋白试验阳性患者交叉配血方法探讨[J].现代检验医学杂志,2015,30(04):130-132.[doi:10.3969/j.issn.1671-7414.2015.04.039]
 LI Jian-gang,ZHAO Jia-ning,XU Hua,et al.Exploration of Appropriate Cross-Matching Methods for Positive Patients of the Direct Antiglobulin Test[J].Journal of Modern Laboratory Medicine,2015,30(04):130-132.[doi:10.3969/j.issn.1671-7414.2015.04.039]
点击复制

直接抗人球蛋白试验阳性患者交叉配血方法探讨()
分享到:

《现代检验医学杂志》[ISSN:/CN:]

卷:
第30卷
期数:
2015年04期
页码:
130-132
栏目:
研究简报·实验技术
出版日期:
2015-08-10

文章信息/Info

Title:
Exploration of Appropriate Cross-Matching Methods for Positive Patients of the Direct Antiglobulin Test
文章编号:
1671-7414(2015)04-130-03
作者:
李建刚1赵家宁1徐 华2姚锁良3
1.西安市第四医院输血科,西安 710004;
2.陕西省血液中心,西安710061;
3.西安交通大学医学院附属红会医院输血科,西安 710054
Author(s):
LI Jian-gang1ZHAO Jia-ning1XU Hua2YAO Suo-liang3
1.Department of Blood Transfusion Service,the Fourth Hospital of Xi'an,Xi'an 710004,China;
2.Blood Center of Shaanxi Province,Xi'an 710061,China;
3.Department of Blood Transfusion,Red Cross Hospital Affiliated to Medical College of Xi'an Jiao
关键词:
直接抗人球蛋白试验 交叉配血 洗涤红细胞
分类号:
R457.12
DOI:
10.3969/j.issn.1671-7414.2015.04.039
文献标志码:
A
摘要:
目的 探讨直接抗人球蛋白试验(DAT)阳性患者的交叉配血方法。方法 采用DAT法筛查红细胞表面的不规则抗体,微柱凝胶法进行血型鉴定,凝聚胺法和抗人球蛋白法交叉配血。结果 共计5例DAT阳性的疑难配血患者,其血型分别为A-DCcEe,O-DCCee,O-DCcee,A-DCCee和A-DCcee。选择相应血型抗原阴性的供者血样进行交叉配血,凝集强度均弱于自身对照,建议观察输注洗涤红细胞,患者未发生不良反应。结论 对于DAT阳性的患者,可配合性输注相应血型抗原阴性的洗涤红细胞。
Abstract:
Objective To investigate the appropriate cross-matching methods for the direct antiglobulin test(DAT)positive patients.Methods The DAT was used to screen the irregular antibodieson the surface of erythrocytes.The microcolumn gel test was used for blood identification.The antiglobulin test and manual polybrene test were used for cross-matching.Results A total of five DAT positive cases were collected in study.The blood groups of each case were detected,including A-DCcEe,O-DCCee,O-DCcee,A-DCCee and A-DCcee.The donor samples with corresponding blood-antigen negative were chosen for cross-matching,and the agglutination intensity of each cross-matching tube was weaker than the control.Thetransfusion of washed red blood cells was suggested.Finally,each transfusion was safe and efficient.Conclusion The infusion of the washed red blood cells with corresponding blood-antigen negative could efficientlyensure the safety of blood transfusion.

参考文献/References:

[1] 叶应妩,王毓三,申子瑜.全国临床检验操作规程[S].3版.南京:东南大学出版社,2006.
Ye YW,Wang YS,Shen ZY.National guide to clinical laboratory procedures[S].Beijng: Publishing House of Southeast University,2006.
[2] 钟月华.微柱凝胶技术在直接抗球蛋白试验中的应用[J].现代检验医学杂志,2011,26(4):8-9.
Zhong YH.The application of microtubes gel technology in direct antglobulin test[J].J Mod Lab Med,2011,26(4):8-9.
[3] 陈轶珏,吴 颖,张晓琪,等.直接抗人球蛋白试验阳性AIHA患儿抗体分型结果分析[J].现代检验医学杂志,2009,24(5):126-127.
Chen YJ,Wu Y,Zhang XQ,et al.The analysis of the antibody typingresults for children with autoimmune hemolytic anemia[J].J Mod Lab Med,2009,24(5):126-127.
[4] 马曙轩,徐樨巍,宋文琪,等.不同疾病RhD阴性患者成分输血策略探讨[J].现代检验医学杂志,2009,24(1):151-153.
Ma SX, Xu XW, Song WQ,et al.Exploration the strategies of bloodcomponents transfusion in RhD negative recipients with different diagnosis[J].J Mod Lab Med, 2009,24(1):151-153.
[5] Dinardo CL,Bonifácio SL,Mendrone A.Indirect an-tiglobulin test-crossmatch using low-ionic-strength saline-albumin enhancement medium and reducedincubation time:effectiveness in the detection of most clinically significantantibodies and impact on blood utilization[J].Immunohematology,2014,30(1):1-5.
[6] Chaudhary RK,Das SS.Autoimmune hemolytic anemia:From lab to bedside[J].Asian J Transfus Sci,2014,8(1):5-12.
[7] Ahrens N,Pruss A,K(¨overa)hne A,et al.Coexistence of autoantibodies and alloantibodies to red blood cells due to blood transfusion[J].Transfusion,2007,47(5):813-816.
[8] Gehrie EA,Tormey CA.The influence of clinical and biological factors ontransfusion-associated non-ABO antigen alloimmunization:responders,hyper-responders,and non-responders[J].Transfus Med Hemother,2014,41(6):420-429.
[9] Reardon JE,Marques MB.Laboratory evaluation and transfusion support ofpatients with autoimmune hemolytic anemia[J].Am J Clin Pathol,2006,125(Suppl 1):S71-S77.

相似文献/References:

[1]王 庆,陈涌泉,王厚照,等.p血型引起交叉配血不合一例分析[J].现代检验医学杂志,2015,30(01):114.[doi:10.3969/j.issn.1671-7414.2015.01.032]

备注/Memo

备注/Memo:
作者简介:李建刚(1968-),男,副主任检验师,从事临床输血工作,Tel:18292170619,E-mail:panpanjianing@163.com。
更新日期/Last Update: 2015-08-10