[1]李德中,周 讯,谢华玉,等.攀枝花市五家医学实验室尿素和肌酐检测结果的比对研究[J].现代检验医学杂志,2015,30(03):90-93.[doi:10.3969/j.issn.1671-7414.2015.03.026]
 LI De-zhong,ZHOU Xun,XIE Hua-yu,et al.Comparative Study of Detection Results of Urea Nitrogen and Creatinine for Five Medical Laboratory[J].Journal of Modern Laboratory Medicine,2015,30(03):90-93.[doi:10.3969/j.issn.1671-7414.2015.03.026]
点击复制

攀枝花市五家医学实验室尿素和肌酐检测结果的比对研究()
分享到:

《现代检验医学杂志》[ISSN:/CN:]

卷:
第30卷
期数:
2015年03期
页码:
90-93
栏目:
论著
出版日期:
2015-06-10

文章信息/Info

Title:
Comparative Study of Detection Results of Urea Nitrogen and Creatinine for Five Medical Laboratory
文章编号:
1671-7414(2015)03-090-05
作者:
李德中1周 讯1谢华玉2梁朝坤2李 洪3张利军4李朝金5
1.攀枝花市临床检验中心、攀枝花市攀钢集团总医院检验科,四川攀枝花 617023;
2.攀枝花市攀钢集团密地医院检验科,四川攀枝花 617063;
3.攀枝花市第二人民医院检验科, 四川攀枝花 617065;
4.攀枝花市妇幼保健院检验科,四川攀枝花 617000;
5.攀枝花市第六人民医院检验科,四川攀枝花 617023
Author(s):
LI De-zhong1ZHOU Xun1XIE Hua-yu2LIANG Chao-kun2LI Hong3ZHANG Li-jun4LI Chao-jin5
1.Department of Clinical Laboratory,General Hospital of Panzhihua Iron and Steel Group,Sichuan Panzhihua 617023,China;
2.Department of Clinical Laboratory,MIDI Hospital of Panzhihua Iron and Steel Group,Sichuan Panzhihua 617063,China;
3.Depart
关键词:
医学实验室 生化检测系统 比对试验
分类号:
R446.112
DOI:
10.3969/j.issn.1671-7414.2015.03.026
文献标志码:
A
摘要:
目的 探讨实验室间不同生化检测系统结果的可比性,为推动实验室间检验结果的互认提供参考。方法 五家实验室检测病人新鲜血清,连续20次分别测定Urea和Cr等10个生化项目,进行精密度分析; 参照美国临床和实验室标准协会(CLSI )EP9-A2文件,以攀钢集团总医院生化检测系统作为比较系统,其余四家医院生化检测系统作为待评系统,检测病人新鲜血清,均分别检测五个生化组合项目(Urea,Cr),(AST,ALT),(TP,ALB),(TG,TC)和(HDL-C,LDL-C),每个组合项目连续测定5天,测定结果进行比对分析,计算比较系统和待评系统之间的相关系数、直线回归方程和不同医学决定水平处的相对偏倚(SE%),并以美国临床实验室改进修正案能力验证(CLIA'88)允许总误差(TEa)的1/2为标准,判断待评系统与比较系统之间的可比性和临床可接受性。结果 以Urea和Cr测定为例,五家实验室间Urea和Cr两项目的CV值均小于CLIA'88允许总误差的1/3,精密度均符合要求。检测结果显著相关(r2>0.975); 临床可接受性能评价中,在Urea低医学决定水平处,有两家实验室的测定结果为临床不可接受; 在Urea高医学决定水平处,有一家实验室的测定结果为临床不可接受; 在Cr低医学决定水平处,有两家实验室的测定结果为临床不可接受; 其余待评系统Urea和Cr项目在各医学决定水平与比较系统比较,其SE%均小于CLIA'88允许总误差的1/2,为临床可接受。结论 实验室间不同生化检测系统的测定结果存在不同程度的偏倚,部分项目偏倚超出允许误差范围。
Abstract:
Objective To investigate the different biochemical testing system inter laboratory comparability of results,provide referencefor promoting inter laboratory test results of the recognition.Methods Five patients with laboratory detection of fresh mixed serum,20 consecutive determination of 10 biochemical items,precision analysis.According to America clinical and Laboratory Standards Institute(CLSI)Document EP9-A2,the Panzhihua Iron and Steel Group General Hospital detection system as the reference system,the remaining four hospital detection system as the detection system,with a fresh mixed serum,determination of five biochemical items(Urea,Cr),(AST,ALT),(TP,ALB),(TG,TC)and(HDL-C,LDL-C),the determination results were compared and analyzed,calculated reference system and the correlationcoefficient,linear regression equation between the system and the various medical decision level relative deviation(SE%),and to America Clinical LaboratoryImprovement Amendment ability test(CLIA'88)allowed total error of 1/2 as thestandard,to the assessment system and the reference system between the comparability and clinical acceptability.Results In Urea,Cr determination for example,CV of five laboratories on Urea and Cr two project was less than CLIA'88 allowed total error of 1/3,the precision could meet the clinical requirements.The detection results significantly correlated(r2>0.975).The evaluation of clinical acceptability,in Urea low at medical decision level,there were two laboratory determination results that could not be accepted for clinical.In Urea high at medical decision level,there was a laboratorymeasurement result that could not be accepted for clinical.In the low Cr at medical decision level,there were two laboratory determination results that couldnot be accepted for clinical.The rest of the system Urea,Cr projects in various medical decision level compared with the system,the SE% was less than CLIA'88 allowed total error of 1/2,for clinical acceptable.ConclusionLaboratory determination results between different biochemical testing system had bias in different degrees,bias part of the project exceeds the allowed error range.

参考文献/References:

[1] 秦晓光.“检验结果互认”和质量管理[J].中华检验医学杂志,2007,30(2):132-135.
Qin XG.Examination results mutual approve and qu-ality management[J].Chinese Journal of Laboratory Medicine,2007,30(2):132-135.
[2] 高小明,何宝明,冯 莉,等.汉中市二级以上医院之间生化检验结果的比对研究[J].现代检验医学杂志,2010,25(4):155-158.
Gao XM,He BM,Feng L,et al.Hanzhong city 2 level and above between hospital biochemical test results than to study[J].Journal of Modern Laboratory Medicine,2010,25(4):155-158.
[3] Clinical and Laboratory Standards Institute.Method comparison and bias estimation using patient samples; approved guideline-second edition[S].Wayne:PA,CLSI EPP-A2,2002:1-8.
[4] 孙 健,蒋廷旺,钱建平,等.4台全自动生化分析仪结果可比性研究[J].国际检验医学杂志,2013,34(23):3222-3223.
Sun J,Jiang TW,Qian JP,et al.4 sets of automatic biochemical analyzer results comparable study[J].International Journal of Laboratory Medicine,2013,34(23):3222-3223.
[5] 邱 玲,程歆琦,刘 荔,等.多台生化分析仪多项目同时进行比对的实验研究设计及应用[J].中华医学检验杂志,2007,30(9):1001-1004.
Qiu L,Cheng XQ,Liu L,et al.Design of method comparison and biasestimation of multi test on multi instrments[J].Chinese Journal of LaboratoryMedicine,2007,30(9):1001-1004.
[6] 乔 林,李德中,周 迅,等.罗氏系统与国产试剂/7170A检测TC,TG结果的偏倚评估[J].现代检验医学杂志,2005,20(4):14-17.
Qiao L,Li DZ,Zhou X,et al.Bias estimation of TC and TG results by roche system and homemade reagent/7170A[J].Journal of Modern Laboratory Medicine,2005,20(4):14-17.
[7] 吕 慧,赖战峰,李海炜,等.血尿素氮、肌酐及尿酸在两种生化分析系统的比对和偏倚评估[J].中华检验医学杂志,2012,35(6):550-553.
LvH,Lai ZF,Li HW,et al.Comparison and bias analysis ofBUN,Cr and UA between two different biochemical analysls systems[J].ChineseJournal of Laboratory Medicine,2012,35(6):550-553.
[8] 中华人民共和国国家卫生和计划生育委员会.WS/T 407-2012医疗机构内定量检验结果的可比性验证指南[S].北京:中国标准出版社,2012.
National Health and Family Planning Commission of the People's Republic of China.WS/T 407-2012 Guideline for comparability verification of quantitative hesults within one health care system[S].Beijing:China Stardard Publishing House,2012.
[9] 中华人民共和国国家卫生和计划生育委员会.WS/T 403-2012临床化学生物化学检验常规项目分析质量指标[S].北京:中国标准出版社,2012.
National Health and Family Planning Commission of the People's Republic of China.WS/T 403-2012 Analytical quality specifications for rouitine analytes in clinical biochemistry[S].Beijing:China Stardard Publishing House,2012.
[10] 中国实验室国家认可委员会技术委员会医学分委会.医学实验室质量管理与认可指南[M].北京:中国计量出版社,2004:72-75.
National Laboratory Accreditation Council for Te-chnical Committee's Medical Board in China.Medical laboratory quality management and approval guidelines[M].Beijing:China Metrology Publishing House,2004:72-75.
[11] 李 莉,陈宝锦,谭榜云,等.两台全自动生化分析仪部分项目检测结果比对和偏倚评估[J].国际检验医学杂志,2011,32(12):1356-1358.
Li L,Chen BJ,Tan BY,et al.Part two full automatic biochemical analyzertest project results comparison and bias evaluation[J].International Journalof Laboratory Medicine,2011,32(12):1356-1358.
[12] 乔 林,李德中,周 迅,等.应用新鲜冷冻血浆进行TC,TG准确度传递研究[J].四川医学,2009,30(6):960-961.
Qiao L,Li DZ,Zhou X,et al.Research of accuracy transfer of cholesteroland triglyceride by fresh mixed refrigerated plasma[J].Sichuan Medical Journal,2009,30(6):960-961.

备注/Memo

备注/Memo:
作者简介:李德中(1968-),男,本科,副主任检验师,主要从事临床生化检验,Tel:15082361179。
更新日期/Last Update: 2015-06-10