[1]鲁 军,程歆琦,禹松林,等.异嗜性抗体干扰化学发光方法检测cTnI的处理和分析[J].现代检验医学杂志,2018,33(02):101-104.[doi:10.3969/j.issn.1671-7414.2018.02.001]
 LU Jun,CHENG Xin-qi,YU Song-lin,et al.Processing and Analysis of cTnI Detected by Heterophilic Antibodies Interference with Chemiluminescence[J].Journal of Modern Laboratory Medicine,2018,33(02):101-104.[doi:10.3969/j.issn.1671-7414.2018.02.001]
点击复制

异嗜性抗体干扰化学发光方法检测cTnI的处理和分析()
分享到:

《现代检验医学杂志》[ISSN:/CN:]

卷:
第33卷
期数:
2018年02期
页码:
101-104
栏目:
研究简报·实验技术
出版日期:
2018-04-05

文章信息/Info

Title:
Processing and Analysis of cTnI Detected by Heterophilic Antibodies Interference with Chemiluminescence
文章编号:
1671-7414(2018)02-101-04
作者:
鲁 军程歆琦禹松林侯立安金 成由婷婷
中国医学科学院 北京协和医学院 北京协和医院检验科,北京 100730
Author(s):
LU JunCHENG Xin-qiYU Song-linHOU Li-anJIN ChengYOU Ting-ting
Department of Clinical Laboratory,Peking Union Medical CollegeHospital, Chinese Academic Medical Science and Peking Union Medical College,Beijing100730,China
关键词:
心肌肌钙蛋白I 干扰 异嗜性抗体
分类号:
R392.3
DOI:
10.3969/j.issn.1671-7414.2018.02.001
文献标志码:
A
摘要:
目的 分析和处理异嗜性抗体干扰心肌肌钙蛋白I(cTnI)免疫测定所导致的假阳性结果。方法 分别采用稀释法、更换检测系统(Beckman,Siemens和Abbott)及异嗜性抗体阻断剂对1例65岁男性患者血浆样本进行处理及检测,比较分析稀释一定倍数、更换检测系统和异嗜性抗体阻断剂处理前后的cTnI结果。结果 使用Beckman系统检测该患者血浆稀释前以及稀释2倍、4倍、8倍的cTnI结果分别为4.60,4.03,3.45和2.62 ng/ml; 使用Beckman,Siemens和Abbott系统检测该患者血浆cTnI的结果分别为4.60,0.023和0.022 ng/ml; 使用Beckman系统检测异嗜性抗体阻断剂处理前后的血浆cTnI结果分别为4.60和0.106 ng/ml。结论该患者血浆cTnI检测受到了异嗜性抗体的干扰,更换检测系统或使用异嗜性抗体阻断剂可以有效解决此类干扰作用。
Abstract:
Abstract:Objective To analyze and deal with false positive results caused by heterophile antibody interference immunoassay.Methods A 65-year-old male patient's plasma samples were processedby dilution method,heterophile antibody blockers and tested using different detection systems(Beckman,Siemens and Abbott),respectively.The results obtained by multiplied dilution and different detection systems as well as pre-and post-processed by heterophilic antibody blockers were compared and analyzed.Results The Beckman system was used to detect plasma cTnI in patients before dilution and multiplied diluted at 2,4 and 8 times,with the results of 4.60,4.03,3.45 and 2.62 ng/ml,respectively.The cTnI results of the patient's plasma determined by Beckman,Siemens and Abbott system were 4.60,0.023 and 0.022 ng/ml,respectively.The plasma cTnI results of before and after heterophilic antibody blockers processing determined by Beckman system were4.60 and 0.106 ng/ml respectively.Conclusion This cTnI assay of the patient's plasma was interfered by heterophile antibodies,andaltering the detection system or utilizing heterophile antibody blockers can solve such interference effectively.

参考文献/References:

[1] Rotmensch S,Cole LA,Rotmensch S,et al.False diagnosis and needless therapy of presumed malignant disease in women with false-positive humanchorionic gonadotropin concentrations[J].Lancet,2000,355(9205):712-715.
[2] Jahagirdar VR,Strouhal P,Holder G,et al.Thyrotoxicosis factitia masquerading as recurrent Graves' disease:endogenous antibody immunoassay interference,a pitfall for the unwary[J].Annals of Clinical Biochemistry,2008,45(Pt3):325-327.
[3] 倪 娟,高洪柳,王国洪,等.化学发光法检测促甲状腺激素结果假性增高1例[J].临床检验杂志,2016,34(9):720. Ni J,Gao HL,Wang GH,et al.Chemiluminescence method for the detection of thyroid stimulating hormone in 1 case[J].Chinese Journal of ClinicalLaboratory Science,2016,34(9):720.
[4] 蒋利君,黎 宇,戴盛明.异嗜性抗体对免疫测定干扰的研究进展[J].分子诊断与治疗杂志,2010,2(1):68-72. Jiang LJ,Li Y,Dai SM.Heterophil antibody interference in immunoassay[J].Journal of Molecular Diagnosis and Therapy,2010,2(1):68-72.
[5] Bonetti A,Monica C,Bonaguri C,et al.Interference by heterophilic antibodies in immunoassays:wrong increase of myoglobin values[J].Acta Bio-Medica:Atenei Parmensis,2008,79(2):140-143.
[6] 韦 维,戴盛明.异嗜性抗体在免疫测定中干扰的研究进展[J].国际检验医学杂志,2010,31(10):1123-1126. Wei W,Dai SM.Research progress of heterophilic antibodies in immunoassay[J].International Journal of Laboratory Medicine,2010,31(10):1123-1126.
[7] 王 焰,黄晓雪,马 莉,等.异嗜性抗体对化学发光检测结果的影响[J].贵阳医学院学报,2013,38(1):94-96. Wang Y,Huang XX,Ma L,et al.Effect of heterophile antibodies on chemiluminescence detection results[J].Jouranl of Guiyang Medical College,2013,38(1):94-96.
[8] 张 娟,韦 清,刘君君.EP14-A3文件在试剂内源性抗体干扰研究中的应用[J].国际检验医学杂志,2015,36(17):2533-2535. Zhang J,Wei Q,Liu JJ.The application of EP14-A3 in the evaluation of ednogenous antibodies interference in immunoassay reagent[J].International Journal of Laboratory Medicine,2015,36(17):2533-2535.
[9] 唐古生,吴 豫,沈 茜.免疫检测干扰因素的分析、识别和对策[J].中华检验医学杂志,2009,32(7):725-729. Tang GS,Wu Y,Shen Q.Analysis,identification and strategies on interference in immunoassay[J].Chinese Journal of Laboratory Medicine,2009,32(7):725-729.
[10] Emerson JF,Lai KKY.Endogenous antibody interferences in immunoassays[J].Lab Medicine,2013,44(1):69-73.
[11] Grouzmann E,Dayer NC,Bain C,et al.Eliminating heterophilic antibodyinterference for ferritin detection using Olympus F(ab')2 based reagent[J].Clinical Laboratory,2008,54(9/10):355-357.
[12] 张保平,刘 珊,韩艳秋.使用化学发光法检测26 707例血清抗梅毒螺旋体特异性抗体以及结果假阳性率分析[J].现代检验医学杂志,2015,30(2):70-73. Zhang BP,Liu S,Han YQ.Analyze of the false positive rate of serum antitreponema pallidum specific antibody of 26 707 cases detected chemiluminescencemethod[J].Journal of Modern Laboratory Medicine,2015,30(2):70-73.

相似文献/References:

[1]周伶俐,魏力强.临床实验室应用不同检测系统检测血清心肌肌钙蛋白I结果的一致性分析研究[J].现代检验医学杂志,2022,37(02):137.[doi:10.3969/j.issn.1671-7414.2022.02.028]
 ZHOU Ling-li,WEI Li-qiang.Consistency Analysis of Serum Cardiac Troponin I with Different Detection Systems in Clinical Laboratory[J].Journal of Modern Laboratory Medicine,2022,37(02):137.[doi:10.3969/j.issn.1671-7414.2022.02.028]
[2]何成山,刘 洋,徐 正,等.内源性因素对抗体夹心免疫法检测血清心肌肌钙蛋白I的干扰及解决方案研究进展[J].现代检验医学杂志,2024,39(01):186.[doi:10.3969/j.issn.1671-7414.2024.01.035]
 HE Chengshan,LIU Yang,XU Zheng,et al.Research Progress on Interference of Endogenous Factors in Detection of Serum Cardiac Troponin I by Sandwich Antibody Immunoassay and Its Solutions[J].Journal of Modern Laboratory Medicine,2024,39(02):186.[doi:10.3969/j.issn.1671-7414.2024.01.035]

备注/Memo

备注/Memo:
作者简介:鲁 军(1988-),男,大学本科,检验技师,现主要从事临床生化及免疫工作。 通讯作者:程歆琦,研究生,副主任医师,E-mail: 18610207700@qq.com。
更新日期/Last Update: 2018-04-16